SPANDREL AREA IN CURTAIN WALLS
Are we protecting the building... but forgetting the glass?
The Spandrel Zone is one of the most critical areas in a curtain wall system, even though it is usually hidden behind opaque glass.
A typical spandrel assembly may include:
🔹 Rock / Mineral Wool
🔹 Back Pan / Back Panel
🔹 Perimeter Fire Stop / Safing
🔹 Smoke Seal
🔹 Spandrel Glass
These components are essential for fire safety, thermal performance and building protection.
But there is another important aspect that should not be overlooked:
☀️ THERMAL STRESS ON SPANDREL GLASS
Solar radiation can be absorbed by the spandrel glass. When insulation and back-pan components are installed behind the glass, heat dissipation may be restricted, creating a heat-trap condition.
This can increase the temperature difference across the glass and potentially lead to thermal stress and glass breakage if the complete assembly is not properly designed.
⚠️ The solution is NOT to remove the Rock Wool or Fire Stop.
The real solution is to coordinate the complete system:
Fire Safety + Thermal Performance + Glass Selection + Proper Clearance + Thermal Stress Assessment
For example, Viracon recommends maintaining a minimum 1-inch (25 mm) clearance between spandrel glass and insulation in relevant applications.
Are we designing the Spandrel Zone only to protect the building from fire and heat — or are we also considering the thermal conditions that our own design creates for the glass?
A successful curtain wall is not just a collection of components.
It is a complete engineered system.
💬 Have you ever experienced spandrel glass thermal breakage due to heat build-up behind the glass?
I would be interested to hear the experience of other façade professionals.